Installation Location Requirements:
•Dry & ventilated area (recommended: in the distribution room or compartment)
•Avoid high-humidity engine room bilges
•≥50cm clearance from heat sources (engines/exhaust pipes)
•IP67 waterproof but avoid direct spray exposure or soaking in water
No. Series Connection is prohibited when Lithium batteries are used as starter batteries. They must only be paralleled, never series-connected for cranking applications.
Only when the battery is used for deep cycling can it be used in parallel. Please refer to the battery specification sheet for specific details.
LILEAD batteries are compatible with the vast majority of marine engines, including YANMAR, Weichai, MAN, CAT, MTU, VOLVO PENTA, etc.
Under room temperature conditions:
•12V Cranking Batteries (S110, S200) can support 12 consecutive starts of a 12V 3.5kW starter motor.
•24V Cranking Battery (S24110) can support 12 consecutive starts of a 24V 8.5kW starter motor.
LILEAD batteries serve as direct drop-in replacements for lead-acid cranking batteries.Temperature:0-35°C
Relative Humidity:≤60%
State of Charge:30%-50% SOC
Maintenance action: Every 3 months, Charge battery at 0.2-0.5C and discharge at 0.2-0.5C ,then Recharge to 40% SOC at 0.5C.